A. I. Hidron, J. R. Edwards, J. Patel, T. C. Horan, D. M. Sievert et al., Results., Infection Control & Hospital Epidemiology, vol.20, issue.11, pp.996-1011, 2006.
DOI : 10.1186/1476-0711-3-14

S. Vaerenberg, S. Hopkins, and B. Catry, The European centre for disease prevention and control (ECDC) pilot point prevalence survey of healthcare-associated infections and antimicrobial use, pp.4-19, 2012.

A. Ferroni, L. Nguyen, B. Pron, G. Quesne, M. Brusset et al., Outbreak of nosocomial urinary tract infections due to Pseudomonas aeruginosa in a paediatric surgical unit associated with tap-water contamination, Journal of Hospital Infection, vol.39, issue.4, pp.301-307, 1998.
DOI : 10.1016/S0195-6701(98)90295-X

M. Satar and N. Narli, Pseudomonas aeruginosa infections due to electronic faucets in a neonatal intensive care unit, J. Paediatr. Child Health, vol.48, pp.430-434, 2011.

D. Ehrhardt, D. Terashita, and T. English, An Outbreak of Pseudomonas aeruginosa in Neonatal Intensive Care Unit, Los Angeles County, Special Studies Report, pp.53-55, 2006.

E. Bedard, C. Laferriere, D. Charron, C. Lalancette, C. Renaud et al., CONCLUSIONS, Infection Control & Hospital Epidemiology, vol.191, issue.11, pp.1337-1343, 2015.
DOI : 10.1016/j.jhin.2004.11.023

J. T. Walker, A. Jhutty, S. Parks, C. Willis, V. Copley et al., Investigation of healthcare-acquired infections associated with Pseudomonas aeruginosa biofilms in taps in neonatal units in Northern Ireland, Journal of Hospital Infection, vol.86, issue.1, pp.16-23, 2014.
DOI : 10.1016/j.jhin.2013.10.003

J. Wingender, Hygienically Relevant Microorganisms in Biofilms of Man-Made Water Systems, In Biofilm, vol.5, pp.189-238, 2011.
DOI : 10.1007/978-3-642-19940-0_9

M. Trautmann, T. Michalsky, H. Wiedeck, V. Radosavljevic, and M. Ruhnke, Abstract, Infection Control & Hospital Epidemiology, vol.83, issue.01, pp.49-52, 2001.
DOI : 10.1016/S0195-6701(98)90296-1

R. Lavenir, M. Sanroma, S. Gibert, O. Crouzet, F. Laurent et al., water network hospital population: invasion and selection of clonal complexes, Journal of Applied Microbiology, vol.45, issue.Suppl 1, pp.1491-1501, 2008.
DOI : 10.1093/infdis/170.2.377

N. Van-der-mee-marquet, D. Bloc, L. Briand, J. M. Besnier, and R. Quentin, Non-touch fittings in hospitals: a procedure to eradicate Pseudomonas aeruginosa contamination, Journal of Hospital Infection, vol.60, issue.3, pp.235-239, 2005.
DOI : 10.1016/j.jhin.2004.11.023

M. H. Levin, B. Olson, C. Nathan, S. A. Kabins, and R. A. Weinstein, Pseudomonas in the sinks in an intensive care unit: relation to patients., Journal of Clinical Pathology, vol.37, issue.4, pp.424-427, 1984.
DOI : 10.1136/jcp.37.4.424

G. Döring, M. Ulrich, W. Müller, J. Bitzer, L. Schmidt-koenig et al., Generation of Pseudomonas aeruginosa aerosols during handwashing from contaminated sink drains, transmission to hands of hospital personnel, and its prevention by use of a new heating device, Int. J. Hyg. Environ. Med, vol.191, pp.494-505, 1991.

P. Cholley, M. Thouverez, N. Floret, X. Bertrand, and D. Talon, The role of water fittings in intensive care rooms as reservoirs for the colonization of patients with Pseudomonas aeruginosa, Intensive Care Medicine, vol.43, issue.8, pp.1428-1433, 2008.
DOI : 10.1164/ajrccm.160.4.9809031

URL : https://hal.archives-ouvertes.fr/hal-00341665

M. Cuttelod, L. Senn, V. Terletskiy, I. Nahimana, C. Petignat et al., Molecular epidemiology of Pseudomonas aeruginosa in intensive care units over a 10-year period (1998-2007), Clinical Microbiology and Infection, vol.17, issue.1, pp.57-62, 1998.
DOI : 10.1111/j.1469-0691.2010.03164.x

R. Leprat, V. Denizot, X. Bertr, and D. Talon, Non-touch fittings in hospitals: a possible source of Pseudomonas aeruginosa and Legionella spp., Journal of Hospital Infection, vol.53, issue.1, p.77, 2003.
DOI : 10.1053/jhin.2002.1336

A. M. Rogues, H. Boulestreau, A. Lashéras, A. Boyer, D. Gruson et al., Contribution of tap water to patient colonisation with Pseudomonas aeruginosa in a medical intensive care unit, Journal of Hospital Infection, vol.67, issue.1, pp.72-78, 2007.
DOI : 10.1016/j.jhin.2007.06.019

C. Chaidez and C. P. Gerba, Comparison of the microbiologic quality of point-of-use (POU)-treated water and tap water, International Journal of Environmental Health Research, vol.41, issue.4, pp.253-260, 2004.
DOI : 10.1016/0043-1354(74)90135-3

M. Motoshima, K. Yanagihara, K. Fukushima, J. Matsuda, K. Sugahara et al., Rapid and accurate detection of Pseudomonas aeruginosa by real-time polymerase chain reaction with melting curve analysis targeting gyrB gene, Diagnostic Microbiology and Infectious Disease, vol.58, issue.1, pp.53-58, 2007.
DOI : 10.1016/j.diagmicrobio.2006.11.007

A. Nanetti and M. Baccarani, Resolution of a Pseudomonas aeruginosa outbreak in a hematology unit with the use of disposable sterile water filters, Haematologica, vol.91, pp.983-985, 2006.

D. W. Warburton, B. Bowen, and A. Konkle, and its effect upon salmonellae in water:methodology to test bottled water in Canada, Canadian Journal of Microbiology, vol.40, issue.12, pp.987-992, 1994.
DOI : 10.1139/m94-158

G. A. Ortolano, M. B. Mcalister, J. A. Angelbeck, J. Schaffer, R. L. Russell et al., Hospital water point-of-use filtration: A complementary strategy to reduce the risk of nosocomial infection, American Journal of Infection Control, vol.33, issue.5, pp.1-19, 2005.
DOI : 10.1016/j.ajic.2005.03.014

D. Charron, E. Bédard, C. Lalancette, C. Laferrière, and M. Prévost, CONCLUSIONS, Infection Control & Hospital Epidemiology, vol.60, issue.03, pp.311-319, 2015.
DOI : 10.1086/506409

S. Hota, Z. Hirji, K. Stockton, C. Lemieux, H. Dedier et al., Conclusion., Infection Control & Hospital Epidemiology, vol.33, issue.01, pp.25-33, 2009.
DOI : 10.1053/jhin.2000.0880

E. Johansson, C. Welinder-olsson, and M. Gilljam, Genotyping of Pseudomonas aeruginosa isolates from lung transplant recipients and aquatic environment-detected in-hospital transmission, APMIS, vol.2014, issue.122, pp.85-91

H. Schneider, G. Geginat, M. Hogardt, A. Kramer, M. Durken et al., Pseudomonas aeruginosa Outbreak in a Pediatric Oncology Care Unit Caused by an Errant Water Jet Into Contaminated Siphons, The Pediatric Infectious Disease Journal, vol.31, issue.6, pp.31-648, 2012.
DOI : 10.1097/INF.0b013e31824d1a11

R. J. Davis, O. J. Slade, S. Van-hal, B. Espedido, A. Gordon et al., CONCLUSIONS, Infection Control & Hospital Epidemiology, vol.18, issue.09, pp.1058-1064, 2015.
DOI : 10.1056/NEJMra1003071

J. Quick, N. Cumley, C. M. Wearn, M. Niebel, C. Constantinidou et al., Seeking the source of Pseudomonas aeruginosa infections in a recently opened hospital: An observational study using whole-genome sequencing, BMJ Open, vol.4, p.6278, 2014.

R. Van-mansfeld, I. Jongerden, M. Bootsma, A. Buiting, M. Bonten et al., The Population Genetics of Pseudomonas aeruginosa Isolates from Different Patient Populations Exhibits High-Level Host Specificity, PLoS ONE, vol.4, issue.10, 2010.
DOI : 10.1371/journal.pone.0013482.s001

W. Li, D. Raoult, and P. Fournier, Bacterial strain typing in the genomic era, FEMS Microbiology Reviews, vol.33, issue.5, pp.892-916, 2009.
DOI : 10.1111/j.1574-6976.2009.00182.x

A. K. Van-der-bij, R. Van-mansfeld, G. Peirano, W. H. Goessens, J. A. Severin et al., First outbreak of VIM-2 metallo-??-lactamase-producing Pseudomonas aeruginosa in The Netherlands: microbiology, epidemiology and clinical outcomes, International Journal of Antimicrobial Agents, vol.37, issue.6, pp.513-518, 2011.
DOI : 10.1016/j.ijantimicag.2011.02.010

D. Sobral, P. Mariani-kurkdjian, E. Bingen, H. Vu-thien, K. Hormigos et al., A new highly discriminatory multiplex capillary-based MLVA assay as a tool for the epidemiological survey of Pseudomonas aeruginosa in cystic fibrosis patients, European Journal of Clinical Microbiology & Infectious Diseases, vol.6, issue.1, pp.31-2247, 2012.
DOI : 10.1371/journal.ppat.1000725

URL : https://hal.archives-ouvertes.fr/hal-00734023

M. Emaneini, Multiple-locus variable number of tandem repeats (vntr) fingerprinting (mlvf) and antibacterial resistance profiles of extended spectrum beta lactamase (esbl) producing Pseudomonas aeruginosa among burnt patients in tehran, Burns, vol.37, pp.1202-1207, 2011.

J. F. Turton, S. E. Turton, L. Yearwood, S. Yarde, M. E. Kaufmann et al., Evaluation of a nine-locus variable-number tandem-repeat scheme for typing of Pseudomonas aeruginosa, Clinical Microbiology and Infection, vol.16, issue.8, pp.1111-1116, 2010.
DOI : 10.1111/j.1469-0691.2009.03049.x

H. Vu-thien, G. Corbineau, K. Hormigos, B. Fauroux, H. Corvol et al., Multiple-Locus Variable-Number Tandem-Repeat Analysis for Longitudinal Survey of Sources of Pseudomonas aeruginosa Infection in Cystic Fibrosis Patients, Journal of Clinical Microbiology, vol.45, issue.10, pp.3175-3183, 2007.
DOI : 10.1128/JCM.00702-07

URL : https://hal.archives-ouvertes.fr/hal-00192548

L. Li, N. Mendis, H. Trigui, J. D. Oliver, and S. P. Faucher, The importance of the viable but non-culturable state in human bacterial pathogens, Frontiers in Microbiology, vol.36, issue.70, p.258, 2014.
DOI : 10.1371/journal.pone.0062388

A. D5246-15, Standard Test Method for Isolation and Enumeration of Pseudomonas aeruginosa from Water, p.5, 2015.

L. Onteniente, S. Brisse, P. T. Tassios, and G. Vergnaud, Evaluation of the Polymorphisms Associated with Tandem Repeats for Pseudomonas aeruginosa Strain Typing, Journal of Clinical Microbiology, vol.41, issue.11, pp.4991-4997, 2003.
DOI : 10.1128/JCM.41.11.4991-4997.2003

R. Zarrilli, Pseudomonas aeruginosa in a neonatal intensive care unit: Molecular epidemiology and infection control measures, BMC Infect. Dis, vol.9, p.70, 2009.

S. Kotay, W. Chai, W. Guilford, K. Barry, and A. J. Mathers, ABSTRACT, Applied and Environmental Microbiology, vol.83, issue.8, pp.3327-3343, 2017.
DOI : 10.1128/AEM.03327-16

F. Salm, M. Deja, P. Gastmeier, A. Kola, S. Hansen et al., Prolonged outbreak of clonal MDR Pseudomonas aeruginosa on an intensive care unit: contaminated sinks and contamination of ultra-filtrate bags as possible route of transmission?, Antimicrobial Resistance & Infection Control, vol.39, issue.1, p.53, 2016.
DOI : 10.1086/421946

E. Bédard, M. Prévost, and E. Déziel, Pseudomonas aeruginosa in premise plumbing of large buildings, pp.937-956, 2016.

Z. Dwidjosiswojo, J. Richard, M. M. Moritz, E. Dopp, H. Flemming et al., Influence of copper ions on the viability and cytotoxicity of Pseudomonas aeruginosa under conditions relevant to drinking water environments, International Journal of Hygiene and Environmental Health, vol.214, issue.6, pp.485-492, 2011.
DOI : 10.1016/j.ijheh.2011.06.004

E. Bédard, D. Charron, C. Lalancette, E. Déziel, and M. Prévost, culturability following copper- and chlorine-induced stress, FEMS Microbiology Letters, vol.356, issue.2, pp.226-234, 2014.
DOI : 10.1111/1574-6968.12494

D. S. Blanc, I. Nahimana, C. Petignat, A. Wenger, J. Bille et al., Faucets as a reservoir of endemic Pseudomonas aeruginosa colonization/infections in intensive care units, Intensive Care Medicine, vol.191, issue.10, pp.1964-1968, 2004.
DOI : 10.1007/s00134-004-2389-z

M. I. Garvey, C. W. Bradley, J. Tracey, and B. Oppenheim, Continued transmission of Pseudomonas aeruginosa from a wash hand basin tap in a critical care unit, Journal of Hospital Infection, vol.94, issue.1, pp.8-12, 2016.
DOI : 10.1016/j.jhin.2016.05.004

C. S. Lee, K. Wetzel, T. Buckley, D. Wozniak, and J. Lee, Rapid and sensitive detection of Pseudomonas aeruginosa in chlorinated water and aerosols targeting gyrB gene using real-time PCR, Journal of Applied Microbiology, vol.146, issue.4, pp.893-903, 2011.
DOI : 10.1099/00221287-146-10-2385